Uninterruptible Power Supply No Break High Frequency UPS 1-3kVA

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Guangdong

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-22 11:25

  • Browse the number:

    254

Send an inquiries

Company Profile

Shenzhen UPSEN Electric Co., Ltd.

By certification [File Integrity]

Contact:Ms. Sophia(Mr.)  

Email:

Telephone:

Phone:

Area:Guangdong

Address:Guangdong

Website: http://upsenpower.youandmechina.net/

Product details

China Uninterruptible Power Supply No Break high frequency UPS 1-3Kva (1ph in/1ph out) 

Key Features:
1: DSP Technology.
2: Environment Friendly And eco-designed
3: Active input power factor correction (PFC)
4: Wide range of input voltage and frequency
5: Zero power switch delay No Break UPS
6: Active Load Management
7: Sufficient Expansion Slots
8: The load power factor is 0.8
9: Generator Supportable
10: Large-screen LCD
11:High Frequency Online UPS
 


Technical Specification

GREEN STAR ONLINE UPS SELECTION GUIDE
MODEL G1K (L) G2K (L) G3K (L)
PHASE Single phase with ground
CAPACITY 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W
INPUT
Nominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC
Input Voltage Range  55-145 VAC or 110-300 VAC 
Frequency Range   40Hz ~ 70 Hz
Power Factor >= 0.99 @ Nominal Voltage (100% load)
OUTPUT
Output Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC
Voltage Regulation  ± 1%
Frequency Range (Synchronized Range) 47~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode) 50 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion <= 3 % THD (Linear Load); <= 6 % THD (Non-linear Load)
Transfer Time AC to DC Zero
Inverter to Bypass 4 ms (Typical)
Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY
To AC Mode 88% 89% 90%
To Battery Mode 83% 87% 88%
BATTERY
Standard Model Battery Type 12 V / 9 AH 12 V / 7AH 12 V / 7 AH
Numbers 2 6 6
Typical Recharge Time 4 hours recover to 90% capacity
Charging Current (max.) 1.0 A
Charging Voltage 27.4VDC ± 1% 82.1 VDC ±1% 82.1 VDC ±1%
Long-run Model* Battery Type Depending on the capacity of external batteries
Numbers 3 6 8
Charging Current (max.) 1.0A/2.0A/4.0A/6.0 A
Charging Voltage 41.0VDC ± 1% 82.1 VDC ±1% 109.4VDC ±1%
INDICATORS
LCD

Load level, Battery level, AC mode, 

Battery mode, Bypass mode, and Fault indicators

ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously sounding
PHYSICAL
Standard Model Dimension, D x W x H (mm) 397 X 145 X 220 419X190X318
Net Weight (kgs) 13 26 28
Long-run Model* Dimension, D x W x H (mm) 282 x 145 x 220 397 X 145 X 220
Net Weight (kgs) 4.6 6.8 7.4
ENVIRONMENT
Humidity 20-90 % RH @ 0- 40°C (non-condensing)
Noise Level Less than 50dBA @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser

* Long-run model is only available in 200/208/220/230/240VAC systems.

Factory shows 

Please contact us freely with any question,We'll give you the suitable solution. Looking forward to cooperating with you.